GAMP Lifetechhome page

Microbial Air Sampling System

Viable air monitoring from online and portable microbial air samplers in one system — every sample tied to its location, plate and colony count, and checked against its limits.

Download the MAS product sheet (PDF, 183 KB)
An MAS sampling round in the filling suite on a tablet: Grade A and B locations with active and passive samplers, plate status and counts, and the week's counts at the airlock against alert and action limits; a portable air sampler, an online sampler head and a settle plate with its tracking label

Overview

What is microbial air sampling?

A microbial air sampler draws a measured volume of cleanroom air across a culture plate, which is then incubated and its colonies counted. EU GMP Annex 1 expects viable monitoring in Grade A for the full duration of critical processing, and sets limits for every cleanroom grade.

Online samplers run at fixed points in the critical zone; portable samplers are carried from point to point on a sampling round. On paper, each sample becomes a label on a plate and a line in a logbook, and days later a colony count copied in from the incubator — where a count over its limit is noticed only when someone reads the sheet.

MAS keeps both kinds of sampler in one record. Each sample is known by where it was taken and on which plate, and its count is checked against the limits as it is entered.

Which location did this plate come from — and was its count over the limit?

In GAMP MAS:

  1. Planned: Locations and frequency by room and grade
  2. Sampled: Online at fixed points, or portable on a round
  3. Incubated: Each plate tracked from media lot to read-out
  4. Counted: Checked against alert and action limits
  5. Trended: By location, room and grade

Every round runs to the same sampling plan

Why GAMP

Why teams choose GAMP MAS

Online and portable, one record

Continuous sampling from online samplers in the critical zone and scheduled rounds with portable ones, recorded the same way against the same locations.

Audit trail on every action

GAMP MAS · in this workflow

  • Online samplers for continuous viable monitoring in critical zones
  • Portable samplers for scheduled sampling rounds

Every plate accounted for

The sampling plan decides what is sampled where, by room and grade, and each plate is tracked from its media lot through incubation to its count.

E-signatures under 21 CFR Part 11

GAMP MAS · in this workflow

  • Sampling plans by room, grade and location
  • Plate tracking from media lot through incubation

Limits and trends, not just counts

Colony counts are checked against alert and action limits as they are entered, and trended by location, room and grade.

Role-based access on every record

GAMP MAS · in this workflow

  • Colony counts checked against alert and action limits
  • Trend reports by location, room and grade

The complete system

Samplers in the room, counts in MAS

MAS works with GAMP microbial air samplers, active and passive, online and portable, and with the samplers you already use. Every sample is tied to its location and plate, and its count checked against limits.

1In your facility

GAMP hardware

2GAMP software

The module and its base

3What you get

From the record

Hardware · GAMP

Active air samplers

Draw a measured volume of air for viable monitoring.

How it connects

Active air samplerssample runsGAMP MAS
1 of 8
Works with your existing hardware

MAS also works with air samplers from other makers. Connecting another maker’s hardware is an integration project, carried out with that manufacturer and your team.

Hardware is supplied by GAMP Services Limited, our parent company. Buy the software on its own or as the complete system through us; hardware on its own through GAMP Services Limited.

Where it sits

One module of FacilityOne

FacilityOne’s modules share single sign-on and one administration layer, and readings, studies and samples can be linked across them.

FacilityOne overview

Benefits

What GAMP MAS gives you

Across FacilityOne

  • Every controlled space in one place

    Monitoring, mapping and microbial air sampling run on one platform with one administration layer, so every room, chamber and cleanroom is managed in the same place.

  • Continuous, not periodic

    Conditions are proven around the clock rather than at whatever moment somebody happened to take a reading.

  • No separate logbooks

    Online and portable results sit side by side, so nothing is copied from one logbook to another.

  • Missing reads show up

    Because every plate is tracked, one that goes missing or is read late stands out instead of surfacing at batch review.

  • Limits checked as you go

    A count over its alert or action limit is flagged the moment it is entered, not when someone next reads the sheet.

  • Continuous where it matters

    Online samplers keep sampling the critical zone for as long as the process runs.

  • Rounds that follow the plan

    Portable sampling rounds follow the sampling plan, location by location, room by room.

  • Drift seen early

    Trending across locations and grades shows a slow rise before it becomes an excursion.

FAQs

Questions teams ask before they start

Is it compliant with 21 CFR Part 11 and EU Annex 11?

It provides the technical controls both regulations require: unique logins, a secure computer-generated audit trail on every action, e-signatures that record who signed, when and what the signature means, and role-based access on every record. Compliance also depends on how the system is validated and used at your site.

Which regulations and standards is it built against?

EU Annex 11 and 21 CFR Part 11 for electronic records and signatures; GMP, including EU GMP Annex 1 for sterile manufacture; WHO GDP for storage and distribution; GAMP 5 for the validation approach; ALCOA++ for data integrity; and ISO/IEC 17025 for calibration.