EU GMP Annex 11, explainedComputerised systems the way EU inspectors expect them
Annex 11 is the EU GMP guideline for every computerised system used in GMP work, from a quality management system to a temperature monitoring system. It is short, risk-based, and applied by inspectors across the EU and PIC/S. This guide covers each of its sections, the 2025 draft revision and how it compares with Part 11.
- Issued by
- European Commission, EU GMP Guide (EudraLex Volume 4); the PIC/S GMP Guide carries the same annex
- Applies to
- All computerised systems used as part of GMP-regulated activities, at sites making medicines for the EU and PIC/S markets
- In force
- Since 30 June 2011. A revised draft was published for public consultation in July 2025
In plain words
What EU GMP Annex 11 is about
Annex 11's principle is simple: when a computerised system replaces a manual operation, there must be no loss of product quality, process control or quality assurance, and no increase in overall risk. The application must be validated and the IT infrastructure qualified.
Unlike Part 11, it follows the system's life. It starts with risk management, people and suppliers. Then it covers what must happen while the system is built and validated (the project phase), and the controls that keep it validated while it is used (the operational phase).
In July 2025 the European Commission published a much longer draft for public consultation, which ran from 7 July to 7 October 2025, alongside a new Annex 22 on artificial intelligence. The draft adds lifecycle validation under quality risk management, and stronger expectations on access, audit trails and security. Annex 22 covers only static, deterministic AI models; generative and continuously learning models are outside it. As of November 2026 neither is final, and the 2011 text is the one inspectors apply.
What it asks for
The requirements, clause by clause
- 1
Risk management
Applied across the lifecycle, with patient safety, data integrity and product quality in view. The extent of validation and data integrity controls rests on a justified, documented risk assessment.
- 2
Personnel
Process owner, system owner, Qualified Persons and IT work closely together, and everyone has the qualifications, access level and responsibilities their role needs.
- 3
Suppliers and service providers
Formal agreements, stating responsibilities, with any third party that supplies, hosts, maintains or validates a system; your own IT department is treated the same way. Whether to audit is decided by risk, off-the-shelf documentation is checked against your requirements, and supplier quality and audit information is available to inspectors.
- 4
Validation
Validation evidence across the lifecycle, an up-to-date inventory of GMP systems, a current system description for each critical system, user requirements traceable through the lifecycle, documented tests, and checks that migrated data is unchanged in value and meaning.
- 5–6
Data and accuracy checks
Built-in checks for correct and secure data exchange. Critical data entered by hand gets an additional check by a second person or a validated electronic means.
- 7
Data storage
Data protected physically and electronically and readable for the whole retention period, with regular backups whose restore is tested.
- 8
Printouts
Clear printed copies. For batch release, printouts should show whether data has changed since it was first entered.
- 9
Audit trails
Based on risk, the system records all GMP-relevant changes and deletions, with the reason. Audit trails are available in a readable form and regularly reviewed.
- 10
Change and configuration management
Changes to the system are made in a controlled way, under a defined procedure.
- 11
Periodic evaluation
Systems are evaluated periodically to confirm they remain validated and compliant.
- 12
Security
Physical and logical controls, such as keys, pass cards, personal codes with passwords or biometrics, limit access to authorised people, as tightly as the system's criticality calls for. Creating, changing and cancelling access is recorded, and the system records who entered, changed, confirmed or deleted data, and when.
- 13
Incident management
All incidents, not only system failures and data errors, are reported and assessed; the root cause of a critical incident feeds CAPA.
- 14
Electronic signature
Same impact as a handwritten signature within the boundaries of the company, permanently linked to its record, and including the date and time it was applied.
- 15
Batch release
Only a Qualified Person certifies a batch; when the system records certification, it uses an electronic signature.
- 16
Business continuity
Defined, tested arrangements keep critical processes running if the system breaks down.
- 17
Archiving
Archived data stays accessible, readable and intact, including after changes to the system.
Where inspections find gaps
Where sites usually slip
- No inventory, no risk basisNo current list of GMP computerised systems, or validation effort with no documented risk assessment behind it.
- Suppliers taken on trustA supplier relied on without an agreement, an assessment or an audit proportionate to risk.
- Audit trails nobody readsAudit trails switched on but never reviewed, or not covering the GMP-relevant changes.
- Leavers still activeAccounts left open after people leave, and access changes made without a record.
- Untested backupsBackups taken for years, but restore never tested.
- Drift after go-liveNo periodic evaluation, so the system moves away from its validated state one change at a time.
What to ask of software
Questions for any vendor
At a glance
Part 11 and Annex 11 side by side
Most regulated manufacturers that export work to both. The two cover the same ground from different directions: Part 11 is a short US regulation about records and signatures; Annex 11 is an EU guideline about the whole life of a computerised system.
| 21 CFR Part 11 (US FDA) | EU GMP Annex 11 | |
|---|---|---|
| Legal form | Federal regulation (1997), binding in the US | Guideline in the EU GMP Guide (2011); also used by PIC/S inspectorates |
| What it covers | Electronic records required by FDA rules, and electronic signatures | Every computerised system used in GMP activities, across its lifecycle |
| Risk | Narrowed by FDA's 2003 guidance to a risk-based scope | Risk management across the lifecycle is the first section |
| Audit trail | Computer-generated, time-stamped record of create, modify and delete, kept at least as long as the records (§11.10(e)) | Based on risk; records GMP-relevant changes and deletions with the reason, readable and regularly reviewed (9) |
| Electronic signature | Name, date, time and meaning; linked to the record; two components; a hand-signed certification to FDA (§11.50–11.300) | Same effect as a handwritten signature within the company, permanently linked, with date and time (14) |
| Suppliers | Not addressed directly | Formal agreements; supplier assessment and audits based on risk (3) |
| Keeping it validated | Validation and system documentation control (§11.10(a), (k)) | Change and configuration management, periodic evaluation, incident management (10, 11, 13) |
| Continuity and archive | Records protected and retrievable for the retention period (§11.10(c)) | Backups with tested restore, business continuity and archiving (7, 16, 17) |
| Status | Requirements unchanged since 1997; FDA guidance explains how it applies them | 2011 text in force; a revised draft went to consultation in July 2025 and is not yet final |
Where GAMP Lifetech helps
The modules behind EU GMP Annex 11 records
- QMSComplianceOneQuality Management SystemVendor qualification and oversight for section 3, change control with impact assessment for section 10, and deviations and CAPA for section 13.See the module
- UAMComplianceOneUser Access ManagementAccess to your GxP systems, instruments and equipment requested, approved, changed and removed through one recorded route: section 12's record of access creation, change and cancellation.See the module
- ADMINEvery platformSystem AdministratorUsers, roles, plants and password policy managed once for every GAMP module, with an activity log and audit trail for every administrative action.See the module
- DMSComplianceOneDocument Management SystemValidation protocols, reports and SOPs under version control and controlled issuance: the documentation section 4 asks for.See the module
- TMSComplianceOneTraining Management SystemTraining and competency records for system users and owners: section 2's appropriate qualifications.See the module
Every GAMP Lifetech module keeps its own computer-generated audit trail, electronic signatures and role-based access, with single sign-on across the suite through System Administrator.
Each release ships with a validation package, so your team builds its own risk-based validation on supplier evidence instead of starting from a blank page.
FAQs
Questions people ask about EU GMP Annex 11
Is EU GMP Annex 11 legally binding?
Annex 11 is part of the EU GMP Guide (EudraLex Volume 4), which sets out how binding EU GMP law is applied. Inspectors in the EU and PIC/S member countries use it, so for a GMP site it works as a requirement.
Does Annex 11 apply to manufacturers in India?
It applies to sites making medicines for the EU market and is used by PIC/S inspectorates. Indian sites exporting to Europe, or inspected by a PIC/S member authority, are held to it.
What is the difference between Annex 11 and 21 CFR Part 11?
Part 11 is a US regulation focused on electronic records and signatures. Annex 11 is an EU guideline covering the whole lifecycle of any GMP computerised system, including suppliers, validation, periodic evaluation and business continuity. Most of their requirements overlap; the table on this page compares them.
Does Annex 11 require audit trail review?
Yes. Section 9 says audit trails should be available, convertible to a readable form and regularly reviewed. How often depends on risk; many sites review the audit trails of critical data before batch release.
Does Annex 11 cover IT departments and hosting providers?
Yes. Section 3 asks for formal agreements, with clear responsibilities, whenever a third party provides, installs, configures, integrates, validates, maintains (including by remote access), modifies or retains a system or service, or processes data. A hosting provider is one such third party, and your own IT department is to be treated the same way.
Has Annex 11 been revised?
Not yet. A substantially revised draft went to public consultation from 7 July to 7 October 2025, together with a new Annex 22 on artificial intelligence. As of November 2026 the final text has not been published, so the 2011 version applies until the revision is published and comes into operation.
Keep reading
Next, read these
- 21 CFR Part 11When electronic records and signatures can replace paper and ink for FDA-regulated work.
FDA
USPart 11
15 requirements9 min read - GAMP 5ISPE's risk-based approach to validating computerised systems, and its software categories.
ISPE
GlobalGAMP 5
8 requirements6 min read - ALCOA++The ten qualities that make a GxP record trustworthy, on paper and in software.
FDA, MHRA, PIC/S, EMA
GlobalALCOA++
5 requirements5 min read
From the library
Official sources
- EU GMP Annex 11: Computerised systems (2011)
- EudraLex Volume 4: EU GMP guidelines
- EU GMP Annex 11 in the GxP glossary
This guide explains EU GMP Annex 11 in plain words; it is not legal advice. Check the current official text before acting on it, and remember that compliance depends on how a system is validated and used, not on the software alone. Last updated .