Annex 11 is the EU GMP guideline for every computerised system used in GMP work, from a quality management system to a temperature monitoring system. It is short, risk-based, and applied by inspectors across the EU and PIC/S. This guide covers each of its sections, the 2025 draft revision and how it compares with Part 11.

Issued by
European Commission, EU GMP Guide (EudraLex Volume 4); the PIC/S GMP Guide carries the same annex
Applies to
All computerised systems used as part of GMP-regulated activities, at sites making medicines for the EU and PIC/S markets
In force
Since 30 June 2011. A revised draft was published for public consultation in July 2025

In plain words

What EU GMP Annex 11 is about

Annex 11's principle is simple: when a computerised system replaces a manual operation, there must be no loss of product quality, process control or quality assurance, and no increase in overall risk. The application must be validated and the IT infrastructure qualified.

Unlike Part 11, it follows the system's life. It starts with risk management, people and suppliers. Then it covers what must happen while the system is built and validated (the project phase), and the controls that keep it validated while it is used (the operational phase).

In July 2025 the European Commission published a much longer draft for public consultation, which ran from 7 July to 7 October 2025, alongside a new Annex 22 on artificial intelligence. The draft adds lifecycle validation under quality risk management, and stronger expectations on access, audit trails and security. Annex 22 covers only static, deterministic AI models; generative and continuously learning models are outside it. As of November 2026 neither is final, and the 2011 text is the one inspectors apply.

What it asks for

The requirements, clause by clause

  1. 1

    Risk management

    Applied across the lifecycle, with patient safety, data integrity and product quality in view. The extent of validation and data integrity controls rests on a justified, documented risk assessment.

  2. 2

    Personnel

    Process owner, system owner, Qualified Persons and IT work closely together, and everyone has the qualifications, access level and responsibilities their role needs.

  3. 3

    Suppliers and service providers

    Formal agreements, stating responsibilities, with any third party that supplies, hosts, maintains or validates a system; your own IT department is treated the same way. Whether to audit is decided by risk, off-the-shelf documentation is checked against your requirements, and supplier quality and audit information is available to inspectors.

  4. 4

    Validation

    Validation evidence across the lifecycle, an up-to-date inventory of GMP systems, a current system description for each critical system, user requirements traceable through the lifecycle, documented tests, and checks that migrated data is unchanged in value and meaning.

  5. 5–6

    Data and accuracy checks

    Built-in checks for correct and secure data exchange. Critical data entered by hand gets an additional check by a second person or a validated electronic means.

  6. 7

    Data storage

    Data protected physically and electronically and readable for the whole retention period, with regular backups whose restore is tested.

  7. 8

    Printouts

    Clear printed copies. For batch release, printouts should show whether data has changed since it was first entered.

  8. 9

    Audit trails

    Based on risk, the system records all GMP-relevant changes and deletions, with the reason. Audit trails are available in a readable form and regularly reviewed.

  1. 10

    Change and configuration management

    Changes to the system are made in a controlled way, under a defined procedure.

  2. 11

    Periodic evaluation

    Systems are evaluated periodically to confirm they remain validated and compliant.

  3. 12

    Security

    Physical and logical controls, such as keys, pass cards, personal codes with passwords or biometrics, limit access to authorised people, as tightly as the system's criticality calls for. Creating, changing and cancelling access is recorded, and the system records who entered, changed, confirmed or deleted data, and when.

  4. 13

    Incident management

    All incidents, not only system failures and data errors, are reported and assessed; the root cause of a critical incident feeds CAPA.

  5. 14

    Electronic signature

    Same impact as a handwritten signature within the boundaries of the company, permanently linked to its record, and including the date and time it was applied.

  6. 15

    Batch release

    Only a Qualified Person certifies a batch; when the system records certification, it uses an electronic signature.

  7. 16

    Business continuity

    Defined, tested arrangements keep critical processes running if the system breaks down.

  8. 17

    Archiving

    Archived data stays accessible, readable and intact, including after changes to the system.

Where inspections find gaps

Where sites usually slip

  • No inventory, no risk basisNo current list of GMP computerised systems, or validation effort with no documented risk assessment behind it.
  • Suppliers taken on trustA supplier relied on without an agreement, an assessment or an audit proportionate to risk.
  • Audit trails nobody readsAudit trails switched on but never reviewed, or not covering the GMP-relevant changes.
  • Leavers still activeAccounts left open after people leave, and access changes made without a record.
  • Untested backupsBackups taken for years, but restore never tested.
  • Drift after go-liveNo periodic evaluation, so the system moves away from its validated state one change at a time.

What to ask of software

Questions for any vendor

0 of 6
Ask for a demonstration of each, not a yes.

At a glance

Part 11 and Annex 11 side by side

Most regulated manufacturers that export work to both. The two cover the same ground from different directions: Part 11 is a short US regulation about records and signatures; Annex 11 is an EU guideline about the whole life of a computerised system.

Part 11 and Annex 11 side by side
21 CFR Part 11 (US FDA)EU GMP Annex 11
Legal formFederal regulation (1997), binding in the USGuideline in the EU GMP Guide (2011); also used by PIC/S inspectorates
What it coversElectronic records required by FDA rules, and electronic signaturesEvery computerised system used in GMP activities, across its lifecycle
RiskNarrowed by FDA's 2003 guidance to a risk-based scopeRisk management across the lifecycle is the first section
Audit trailComputer-generated, time-stamped record of create, modify and delete, kept at least as long as the records (§11.10(e))Based on risk; records GMP-relevant changes and deletions with the reason, readable and regularly reviewed (9)
Electronic signatureName, date, time and meaning; linked to the record; two components; a hand-signed certification to FDA (§11.50–11.300)Same effect as a handwritten signature within the company, permanently linked, with date and time (14)
SuppliersNot addressed directlyFormal agreements; supplier assessment and audits based on risk (3)
Keeping it validatedValidation and system documentation control (§11.10(a), (k))Change and configuration management, periodic evaluation, incident management (10, 11, 13)
Continuity and archiveRecords protected and retrievable for the retention period (§11.10(c))Backups with tested restore, business continuity and archiving (7, 16, 17)
StatusRequirements unchanged since 1997; FDA guidance explains how it applies them2011 text in force; a revised draft went to consultation in July 2025 and is not yet final

FAQs

Questions people ask about EU GMP Annex 11

Is EU GMP Annex 11 legally binding?

Annex 11 is part of the EU GMP Guide (EudraLex Volume 4), which sets out how binding EU GMP law is applied. Inspectors in the EU and PIC/S member countries use it, so for a GMP site it works as a requirement.

Does Annex 11 apply to manufacturers in India?

It applies to sites making medicines for the EU market and is used by PIC/S inspectorates. Indian sites exporting to Europe, or inspected by a PIC/S member authority, are held to it.