WHO GDP and temperature mapping, explainedProving the product stayed in range, from store to vehicle
WHO's good storage and distribution practices, usually called GDP, set out how medical products must be stored and moved so their quality survives the journey. For temperature-sensitive products that comes down to three things: map every storage area, monitor it with calibrated equipment, and keep records you can show an inspector. This guide covers each one, with the numbers WHO's mapping guidance gives.
- Issued by
- World Health Organization: TRS 1025, Annex 7, "Good storage and distribution practices for medical products" (2020)
- Mapping detail
- WHO technical supplement "Temperature mapping of storage areas" (2015), supporting the model guidance in TRS 961, Annex 9
- Applies to
- Everyone who procures, stores, supplies, imports, exports or transports medical products: warehouses, distributors, importers, transporters
In plain words
What WHO GDP is about
TRS 1025 Annex 7 brings WHO's storage and distribution guidance together in one document. It covers the whole chain: quality management, premises, equipment, qualification, documentation and transport.
For temperature, the core rule is short. Store products as their label says; map storage areas; monitor at regular intervals with calibrated equipment; review the records; and keep them as national law requires (12.34–12.37). WHO's technical supplement on temperature mapping turns that into a method.
Mapping and monitoring are different jobs. Mapping is a study: many loggers, for a set period, to find the hot and cold spots of a space. Monitoring is continuous: fixed sensors at the points the mapping showed to be worst-case, with alarms when readings leave their limits. In India's hot, humid summers and monsoon, ambient stores can change a great deal between seasons, which is exactly when WHO's guidance calls for mapping in both the warmest and the coldest season.
What it asks for
The requirements, clause by clause
- 12.34
Label conditions
Storage conditions follow the product's labelling and the manufacturer's information.
- 12.35
Qualified HVAC
Heating, ventilation and air conditioning are designed, installed, qualified and maintained to hold the required conditions.
- 12.36
Mapping
Mapping studies for temperature, and for relative humidity where appropriate, in storage areas, refrigerators and freezers.
- 12.37
Monitoring and records
Temperature and humidity controlled and monitored at regular intervals; data recorded and reviewed; monitoring equipment calibrated; mapping and monitoring records kept as national legislation requires.
- 17.9
Protected records
Records protected against unauthorised access, change, damage or loss for their whole life, and readily retrievable.
- 18.24
Qualified vehicles
Vehicles qualified, where applicable, to show they can hold the required transport conditions, with maintenance of their cooling or heating systems.
- 18.25–18.26
Monitoring in transit
Conditions maintained, monitored and recorded in transit, with records available to inspectors, and the monitoring instruments in vehicles and containers calibrated at regular intervals.
- Supplement 1.1
Map before use, and again after change
Every new temperature-controlled store is mapped before it is commissioned, empty and loaded, marking zones not to use. It is re-mapped after significant change, when monitoring shows unexplained variation, and periodically (for example every three years) depending on the monitoring in place.
Where inspections find gaps
Where sites usually slip
- Probes where it was convenientMonitoring points placed near a socket or a door, not where the mapping found the hot and cold spots.
- Mapped once, years agoA warehouse mapped in one season, before the racking, the loading or the refrigeration changed.
- Excursions found lateOut-of-range readings found at the next manual check rather than alarmed in real time, with no record of the response.
- Calibration gapsLoggers and probes out of calibration, or certificates missing.
- Holes in the recordGaps in the temperature history whenever the network or the power failed.
- MKT as an excuseMean kinetic temperature used after the fact to justify an excursion, with no stability data behind the decision.
What to ask of software
Questions for any vendor
At a glance
A mapping study at a glance
The numbers below are from WHO's technical supplement on temperature mapping of storage areas. Your protocol sets the final values, using a risk-based approach.
| Question | What WHO's mapping guidance says |
|---|---|
| Where do loggers go? | In a grid along the length and width, every 5–10 metres (up to 20–30 metres in very large facilities), at the places products are actually stored |
| At what heights? | Ceiling of 3.6 m or less: high, middle and low (for example floor, 1.2 m and 3.0 m). Higher spaces: arrays at bottom, middle and top (for example 0.3, 1.8, 3.6 and 5.4 m in a 6 m space) |
| For how long? | Warehouses and ambient stores: at least seven consecutive days, including a weekend. Cold rooms and freezer rooms: 24 to 72 hours, or longer if justified; with duplicate refrigeration units, map each one running alone |
| Which seasons? | Where stores are affected by season, map in the warmest and the coldest season. Usually not needed for cold rooms and freezer rooms |
| Which loggers? | Recording interval settable from 1 to 15 minutes; three-point calibration with an error of no more than ±0.5 °C at each point; software that meets requirements such as 21 CFR Part 11 |
| When to re-map? | After significant changes (loading pattern, refrigeration, set point), when monitoring shows unexplained variation, and periodically, for example every three years |
At a glance
WHO recommended storage conditions
From Appendix 1 of TRS 1025 Annex 7 (Table A7.1). Labels should state actual limits wherever possible; "store at ambient conditions" should be avoided.
| Label says | Recommended limits |
|---|---|
| Store at controlled room temperature | 15 to 25 °C |
| Store in a cold or cool place | 8 to 15 °C |
| Store in a refrigerator / chilled | 5 ± 3 °C |
| Store in a freezer | −20 ± 5 °C |
| Store in a deep freezer | −70 ± 10 °C |
| Store in a dry place / protect from moisture | No more than 60% relative humidity |
| Store under ambient conditions | Well-ventilated premises at 15 to 30 °C and no more than 60% relative humidity |
Where GAMP Lifetech helps
The modules behind WHO GDP records
- FMPFacilityOneFacility Mapping SystemTemperature mapping studies for cold rooms, warehouses, chambers and vehicles: logging intervals from 1 to 60 minutes, scheduled start and stop, audit-ready reports with statistics, and calibration by ISO/IEC 17025-accredited laboratories (12.36).See the module
- FMSFacilityOneFacility Monitoring SystemContinuous monitoring with SMS and email alarms, MKT reporting, and readings held on the logger if the network drops (12.37, 18.25).See the module
- QMSComplianceOneQuality Management SystemAn excursion can be raised as a deviation, investigated to root cause and closed with CAPA.See the module
Every GAMP Lifetech module keeps its own computer-generated audit trail, electronic signatures and role-based access, with single sign-on across the suite through System Administrator.
FAQs
Questions people ask about WHO GDP
What is the difference between temperature mapping and temperature monitoring?
Mapping is a study: many data loggers placed across a space for a set period to find its hot and cold spots and prove it holds its limits. Monitoring is continuous: fixed sensors at the worst-case points found by mapping, recording all the time and raising alarms when a reading goes out of range.
How many data loggers does a mapping study need?
WHO's mapping guidance places loggers in a grid every 5–10 metres along the length and width of the space, at high, middle and low levels (more levels in tall stores), wherever products are actually stored. The total depends on the size and layout; a risk-based protocol sets the final number.
How long should a temperature mapping study run?
WHO's guidance gives no formal limit, but typically at least seven consecutive days for warehouses and ambient stores, including a weekend, and 24 to 72 hours for cold rooms and freezer rooms, or longer if justified.
How often should a warehouse be re-mapped?
After any significant change, when monitoring shows unexplained variation, and periodically, for example every three years, depending on the monitoring strategy. Stores affected by the seasons should be mapped in both the warmest and the coldest season.
What is mean kinetic temperature, and can it justify an excursion?
MKT is a single derived temperature that gives the same overall thermal challenge as a fluctuating temperature history over the same period; it is always at or above the simple average. It is useful for reviewing logger data, but it does not replace the labelled storage conditions and should not, on its own, justify an excursion after the fact. That needs product stability data and a documented assessment.
How long must temperature records be kept?
WHO's guidance leaves the period to national legislation: mapping and monitoring records are kept for a suitable time and as national law requires (12.37), and transport monitoring records for a defined period, available to inspectors (18.25).
Keep reading
Next, read these
- ALCOA++The ten qualities that make a GxP record trustworthy, on paper and in software.
FDA, MHRA, PIC/S, EMA
GlobalALCOA++
5 requirements5 min read - 21 CFR Part 11When electronic records and signatures can replace paper and ink for FDA-regulated work.
FDA
USPart 11
15 requirements9 min read - Revised Schedule MIndia's GMP rules, rewritten around a pharmaceutical quality system, risk management and data integrity.
MoHFW and CDSCO
IndiaSch. M
10 requirements6 min read
From the library
Official sources
- WHO TRS 1025, Annex 7: Good storage and distribution practices (2020)
- WHO distribution guidelines and technical supplements
- WHO GDP in the GxP glossary
This guide explains WHO GDP in plain words; it is not legal advice. Check the current official text before acting on it, and remember that compliance depends on how a system is validated and used, not on the software alone. Last updated .