ALCOA++ and data integrity, explainedThe ten qualities every GxP record needs
ALCOA++ is shorthand for what makes a record trustworthy: attributable, legible, contemporaneous, original and accurate, plus complete, consistent, enduring, available and traceable. Regulators use it to judge data integrity on paper and in software alike. Here is what each letter means in practice, which guidance it comes from, and where records usually fail.
- Origin
- ALCOA, usually credited to FDA in the 1990s
- Extended
- ALCOA+ in PIC/S PI 041-1 (2021, section 7.4) and other data integrity guidance; ALCOA++ in EMA's 2023 guideline on computerised systems in clinical trials (section 4.5)
- Applies to
- All GxP data, paper and electronic, for its whole lifecycle
In plain words
What ALCOA++ is about
Data integrity means data stays complete, consistent and accurate throughout its lifecycle, from the moment it is created to the day it is destroyed. ALCOA is how inspectors test that, one attribute at a time.
The first five letters are usually credited to FDA in the 1990s. PIC/S's 2021 data integrity guide adds four more, complete, consistent, enduring and available, as ALCOA+, and applies them to paper, computerised and hybrid systems alike. EMA's 2023 guideline on computerised systems in clinical trials lists ten, ALCOA++, adding traceable and writing available as "available when needed". Different documents word the list slightly differently, but the ideas are the same.
Software does not make data trustworthy on its own. Technical controls such as unique logins, audit trails, locked calculations and backups have to work together with procedures and a culture where problems are reported, not hidden.
What it asks for
The requirements, clause by clause
- FDA 2018
Data integrity and CGMP guidance
Audit trails are part of the record: whoever reviews a record reviews its audit trail, as often as GMP requires for that record, such as before batch release. Shared logins are not acceptable for actions on data, only for read-only viewing, and every GMP workflow on a computer system is validated in proportion to risk.
- MHRA 2018
GxP data integrity guidance and definitions
Sets out the core elements of a compliant data governance system across GxP work, and the supportive organisational culture it depends on.
- PIC/S 2021
PI 041-1, data management and integrity
The inspectors' guide to good data management in GMP and GDP environments. It defines ALCOA+ (section 7.4) and applies it to paper, computerised and hybrid systems.
- WHO 2021
Guideline on data integrity
WHO's data integrity guideline, published as Annex 4 of Technical Report Series No. 1033.
- EMA 2023
Computerised systems in clinical trials
EMA's guideline on computerised systems and electronic data in clinical trials lists the ten ALCOA++ attributes in section 4.5, including available when needed and traceable. Adopted on 7 March 2023, it came into effect six months after publication.
Where inspections find gaps
Where sites usually slip
- Shared loginsOne account used by a whole shift, so no record is attributable.
- Testing into complianceResults re-run until they pass, with the failed runs deleted or never reported.
- Written up afterwardsEntries completed after the shift from memory: neither contemporaneous nor reliable.
- Uncontrolled blank formsWorksheets and forms issued without control, so originals can be replaced.
- Audit trails off or unreadThe audit trail switched off, or on but never reviewed.
- Fragile dataClocks users can change; data held on a local PC with no backup.
What to ask of software
Questions for any vendor
At a glance
The ten attributes, in practice
What each letter asks of a record, with a paper example and the electronic control that delivers it.
| Attribute | What it means | On paper | In software |
|---|---|---|---|
| Attributable | It is clear who created or changed the record, and when | Signature or initials and date on every entry | Unique user accounts, no shared logins, electronic signatures |
| Legible | Readable and permanent for its whole life | Indelible ink; corrections that do not obscure the original | Human-readable records and audit trails that can be printed or exported |
| Contemporaneous | Recorded when the work is done | Entries made at the time, not written up later | System time stamps from a controlled clock |
| Original | The first capture, or a verified true copy | The original batch record, not a transcription | Raw data kept, not just results; controlled copies |
| Accurate | Correct, truthful and checked | Second-person verification of critical entries | Validated calculations, checks on manual entry, calibrated instruments |
| Complete | All the data, including repeats and failures | No pages missing, nothing discarded | Nothing deleted without a trace; every change in the audit trail |
| Consistent | In the expected sequence, dated consistently | Chronological entries | Time-stamped sequence of events; consistent formats |
| Enduring | Lasts for the full retention period | Durable paper in controlled storage | Backups with tested restore, and archiving |
| Available (when needed) | Stored for its whole life and readily retrieved for review and inspection | Indexed, accessible archive | Searchable records that can be produced for an inspector |
| Traceable | Every change can be followed back to the original | Single line through, initialled, with the reason | An audit trail showing who, what, when and why |
Where GAMP Lifetech helps
The modules behind ALCOA++ records
- UAMComplianceOneUser Access ManagementAttributable: one account per person on every GxP system and instrument, granted and removed through a recorded route, with segregation of duties enforced.See the module
- ADMINEvery platformSystem AdministratorAttributable: single sign-on across the suite, password policy set centrally, and an audit trail of every administrative action.See the module
- AICSAsepticOneAseptic Intervention Compliance SystemContemporaneous: interventions captured at the point of action, not written up at the end of the shift.See the module
- FMSFacilityOneFacility Monitoring SystemComplete and enduring: continuous monitoring, with readings held on the logger if the network drops so the record has no gaps.See the module
- DMSComplianceOneDocument Management SystemOriginal and legible: controlled issuance of SOPs and batch records, version control, and transcription managed in the system.See the module
- FMPFacilityOneFacility Mapping SystemAccurate: mapping sensors calibrated by ISO/IEC 17025-accredited laboratories, traceable to national standards.See the module
Every GAMP Lifetech module keeps its own computer-generated audit trail, electronic signatures and role-based access, with single sign-on across the suite through System Administrator.
FAQs
Questions people ask about ALCOA++
What does ALCOA stand for?
Attributable, Legible, Contemporaneous, Original and Accurate: the five qualities a record needs to be trustworthy. ALCOA+ adds Complete, Consistent, Enduring and Available, and ALCOA++ adds Traceable.
What is the difference between ALCOA+ and ALCOA++?
ALCOA+ adds four attributes to the original five: complete, consistent, enduring and available. ALCOA++ adds traceable, meaning every change can be followed back to the original record. It appears in EMA's 2023 guideline on computerised systems in clinical trials; other guidance uses ALCOA+.
Is ALCOA++ a regulatory requirement?
The acronym is shorthand, but the expectations behind it are enforced through GMP and GDP rules (in the US, 21 CFR 211 and Part 11; in the EU, the GMP Guide's Chapter 4 and Annex 11), and they are spelled out in FDA, MHRA, WHO, PIC/S and EMA data integrity guidance.
Does ALCOA apply to paper records?
Yes. Every attribute applies to paper, electronic and hybrid records. Paper has its own controls: indelible ink, issued and reconciled forms, single-line corrections with initials, date and reason.
Can a failed or invalid result be left out of the record?
No. FDA's 2018 data integrity guidance says a result can be invalidated only with a valid, documented, scientifically sound justification. Even then, the batch record given to the quality unit includes the original, invalidated data, with the investigation report that justifies the decision.
How does an audit trail support ALCOA++?
A secure, computer-generated audit trail makes changes attributable and traceable: it records who changed what, when and why, without obscuring the original. It only helps if it is switched on for the data that matters and is actually reviewed.
Keep reading
Next, read these
- 21 CFR Part 11When electronic records and signatures can replace paper and ink for FDA-regulated work.
FDA
USPart 11
15 requirements9 min read - EU GMP Annex 11How every computerised system used in GMP is validated, secured and kept in control across its life.
European Commission
EUAnnex 11
16 requirements7 min read - GAMP 5ISPE's risk-based approach to validating computerised systems, and its software categories.
ISPE
GlobalGAMP 5
8 requirements6 min read
From the library
Official sources
- FDA guidance: Data integrity and compliance with drug CGMP (2018)
- MHRA: GxP data integrity guidance (2018)
- EMA: Computerised systems and electronic data in clinical trials (2023)
- ALCOA++ in the GxP glossary
This guide explains ALCOA++ in plain words; it is not legal advice. Check the current official text before acting on it, and remember that compliance depends on how a system is validated and used, not on the software alone. Last updated .